Inside the Trimble X9: Deep Dive into Trimble X9 Auto-Calibration 4 Internal Collimator Theintegrationofaninternalcollimatorinsidetheinstrumentbaseenablesacompletelyautomatic calibrationprocess.Notargetsoruserinteractionarerequiredtomeasuretheprimaryaxiserrors. Figure 2: Internal Collimator for Trimble X9 Theinternalcollimatorcamerameasuresthelaserbeamemittedbythescannerheadoverthefull radius,whilethealidadedrivesystemturnsthecenterunittodifferentpositions.Theprocessof measuringasingularlineofsighthorizontalandverticalcollimationerrorfromatotalstationis extendedtoincludeinfiniteline-of-sightmeasurementstakenovera360°dome.Thisispossible withtheTrimbleX-Drive'scombinationoftwoverticaldrivesystemslocatedinthealidadeandthe deflectionunitforscanning. Thisauto-calibrationprocedurecomeswithmultipleadvantages.Thefirstbeingthatbecausethe technologyforthealidade'sencodersystemisadoptedfromtotalstations,theprecisionisalready downtolessthan3"(arcseconds)andprovidesconfidencethatthescannerheadwillbeproperly calibratedateachindividualdeflectionunitencoderpositionforbothhorizontalandvertical collimationerror.Theprocedurealsoaccountsforallremainingalignmentdeviationsinsidethe scanneraswellasdeflectionunitencodererrors.Forexample,inthecasethattheEDMbeamand thedeflectionunitrotationaxesarenotidentical,thescanningplanewillnotbeperfect,butrather slightlybent.