Inside the Trimble X9: Deep Dive into Trimble X9 Auto-Calibration 7
Step2:Determinetheerrorinthedeflectionmirror.Whenthe45°deflectionmirrorangleisnot
exactly45°,thescanfanbecomesatiltedcone.
Step3:Determinetheerrorwithalignmentofthedeflectionunitmotoraxis.Whenthedeflection
unitmotoraxisisnotalignedexactlywiththelaserbeam,thetiltedconewillnowhaveasinuson
top.